Effects of Longitudinal Ventilation on Maximum Ceiling Temperature and Its Position in Tunnel Fire

Wei ZHU,Xiao-feng ZHOU,Long-hua HU,Shuai LIU
DOI: https://doi.org/10.3969/j.issn.1009-6094.2012.03.034
2012-01-01
Applied Mechanics and Materials
Abstract:Experimental study of temperature distribution along tunnel ceiling with different longitudinal ventilation velocities and different typical fire sizes was conducted in a combustion wind tunnel with length of 20 m.Both square and rectangular pool fires were used as fire sources for longitudinal ventilation velocities ranged in 0-3 m/s.The smoke temperatures below the ceiling were recorded by K type thermocouple for near fire region and by thermal resistors for that relative far away from the fire source.The results indicate that longitudinal ventilation velocity and fire size have a great influence on temperature distribution.The variation of ceiling temperature distribution with the increase of longitudinal ventilation velocity was shown to be different for a small fire from that for a large fire.For small scale fires,temperature of tunnel ceiling reduced to a stable value with gradual increase of longitudinal ventilation velocity.However,for big scale fire,the temperature increased first,and then decreased.The position of maximum temperature rise point firstly moved downstream horizontally with the increase of the wind speed.When the wind speed reached a certain value,the maximum temperature rise point returned back to an upstream position,and then moved downstream again.This is due to the change of dominant heating mechanism with the increase of longitudinal ventilation velocity.When the longitudinal ventilation velocity is relative small,both convection from hot smoke and radiation from the flame provide considerable contribution.However,when the longitudinal ventilation velocity is relative large,radiation is dominant.The influence of the length of windward side of rectangular pool fire was also discussed.It was shown that when the longitudinal ventilation velocity is relative smaller(0.5-1.5 m/s),the maximum temperature is higher when the longer side is parallel to the wind direction than that under perpendicular condition.However,when the longitudinal ventilation velocity is relative higher(≥2 m/s),the maximum temperature is similar under the above two conditions.
What problem does this paper attempt to address?