Effects of Cross-Midline Cement Distribution on the Stiffness of Varied Sites in Compressive Fractured Vertebrae after Unipedicular PKP:a Biomechanical Study

陈柏龄,谢登辉,黎艺强,庄新明,杨晓曦,于滨生,郑召民
DOI: https://doi.org/10.3969/j.issn.1004-406x.2011.02.07
2011-01-01
Abstract:Objective:To evaluate the effects of cross-midline cement injection on axial and bilateral vertebral stiffness of varied sites in compressive fractured vertebrae after unipedicular PKP.Method:Vertebral bodies harvested from 3 cadaver spines(T4-L1) were experimentally induced into compressive vertebral fractures models by MTS.Subsequently the specimens were stabilized using transpedicular balloon-assisted PKP(group A,n=9,unipedicular hemivertebral,non cross-midline cement injection,group B,n=8,unipedicular cross-midline cement injection) and the volume of cement filling were 10% of the vertebral body.Then the stablized vertebral bodies were subjected to axial and sided compression loads(0-300N,cycled) by MTS 24 hours later.After that,the stiffness was measured and compared between the two groups.Result:Under axial loading,the stiffness between group A and B showed no significant difference(P0.05).While under sided compression loading,despite of no difference of stiffness in penetration side between group A and B(P0.05),the stiffness in non-penetration side in group B increased more than that in group A(P0.05).Conclusion:When performing unipedicular balloon-assisted kyphoplasty,cross-midline cement distribution or not will impact the side-related stiffness significantly.
What problem does this paper attempt to address?