CALCULATION ANALYSIS OF XIEDAO STEEL STRUCTURAL SHED INSPECTION

Chen-xi WEI,Yuan-qing WANG,Tian-shen ZHANG,Zhen WANG
DOI: https://doi.org/10.3969/j.issn.1001-6864.2013.08.018
2013-01-01
Abstract:In order to estimate the safety of the steel structured shed in Xiedao,the section size of grid structure,diameter of member bars,thickness of pipes,length of steel frame,and dimension of sphere joints are inspected.The overall structural model of the project is established with MIDAS.The situations both in carrying capacity limit state and service ability limit state are calculated.The steel shed structure is proved to be in accord with the requirement of the specifications as a result,but several members of the grid have to be reinforced.
What problem does this paper attempt to address?