Design of the Quartz Resonant Force Sensor with Double Diaphragms and Study of Its Performer

WANG Xiaohong,ZHU Huizhong,FENG Guanping
DOI: https://doi.org/10.3321/j.issn:1000-0054.2001.01.028
2001-01-01
Abstract:The structural stability of the sensor correlates with the loss in stability of the resonator. Assuming that the quartz resonator is orthogonally anisotropic and isotropic, the critical force of the resonator when the instability occurrs was calculated using the finite element method. The relationship between the structural stability of the sensor, its thickness and the support design of the resonator was obtained. The stability analyses were used to design quartz resonant force sensor with d ouble diaphragms having high stability, high precision and high reliability. The input and output, creep, stability, etc. of sensors with one diaphragm were compared experimentally with those with double diaphragms. The sensors with double diaphragms performed much better than those with one diaphragm with reduced nonlinear error, hysteresis error, repeatability error and creep error. The hysteresis and repeatability performance is improved significantly. The bias load resisting ability, the transverse impact resisting ability, and the long-term reliability have also been improved.
What problem does this paper attempt to address?