Separated Double-Layer Magnetic Shielding with Magnetic Sensor for Large Current Measurement

Yafeng Chen,Qi Huang,Arsalan Habib Khawaja
DOI: https://doi.org/10.1109/isgt-asia.2018.8467871
2018-01-01
Abstract:One drawback of contactless current measurement by magnetic sensor is that its detected results can be easily affected by the superposition of the external magnetic interference. Damping the effect of the noise is complex and delicate without the knowledge of the interference. The usage of magnetic shielding is one potent way to compensate the shortcoming. However, complete magnetic shielding fails to provide the shielding for the shielding only happens within the material. Therefore, in this paper, a separated double-layer structure with the gap is proposed for large current measurement with strong magnetic noise from random places. The ambition is to keep the targeted magnetic field within the shielding stable even when exposed to strong magnetic interference environment. Parameters of the designed structure are investigated and the validation of the structure is confirmed by finite element analysis method when the magnitude of the current under measurement ranging up to 1000 A. From FEA method, when the interference is at arbitrary places around the conductor, the standard deviation without and with noise is less than 0.13, authenticating the efficacy of this shielding structure.