Hefei Utility Negative Ions Test Equipment with RF Source: Commissioning and First Results

Jianglong Wei,Yahong Xie,Caichao Jiang,Lizhen Liang,Qinglong Cui,Shiyong Chen,Yongjian Xu,Yan Wang,Li Zhang,Yuanlai Xie,Chundong Hu
DOI: https://doi.org/10.1088/2058-6272/aadc06
2018-01-01
Abstract:In order to study the key technology and physics of RF driven negative ion source for neutral beam injector in China, the Hefei utility negative ions test equipment with RF source was developed at Institute of Plasma Physics, Chinese Academy of Sciences (ASIPP). Its negative ion source can be equipped with single or double RF drivers. There is a plasma expansion chamber with depth of 19 mm and an enhanced filter field. A three electrodes negative ion accelerator was employed to extract and accelerate the negative ions, which are plasma grid, extraction grid and ground grid. And there are several diagnostic tools for the plasma and beam parameters measurement. The characteristics of plasma generation, negative ion production and extraction were studied on the test equipment. The negative ion beam was extracted from the RF driven negative ion source for the first time. The detailed structure and main results are presented in this article.
What problem does this paper attempt to address?