Pseudo-dynamic tests of a 1∶10 model of pre-stressed concrete containment vessel for CNP1000 nuclear power plant
Qian Jiaru,Zhao Zuozhou,Duan An,Xia Zufeng,Wang Mingdan
DOI: https://doi.org/10.3321/j.issn:1000-131X.2007.06.002
2007-01-01
Abstract:CNP1000 is the latest developed nuclear power plant in China. The pre-stressed concrete containment vessel (PCCV), consisting of a semi-spherical dome, a cylinder and two buttresses, is a symbolic structure for CNP1000. In order to verify the seismic safety of this new type of PCCV under the design earthquake level of SL-2 (peak acceleration 0.2 g) and to provide the dynamic test data for earthquake resistant design of the structure and technical integration of the PCCV, a series of single-degree of freedom (SDOF) pseudo-dynamic tests of a 1:10 model were carried out. Based on the loading direction, the test was carried out in two stages. For test stage 1, the loading was applied perpendicular to the connection line of the two buttresses, and for test stage 2 the loading was applied along the connection line of the two buttresses. Theoretical mass of the SDOF system for each test stage was determined based on finite element analysis of the test model. An artificial earthquake wave was employed as the input. There were three load cases for each test stage with the peak acceleration being 1 g, 2 g and 3 g, respectively, corresponding to 0.1 g, 0.2 g and 0.3 g for the prototype PCCV structure, and the corresponding damping ratio of the test model was assumed to be 0.02, 0.05 and 0.05, respectively. The test results indicate that under earthquake excitation of a peak acceleration 2 g (corresponding to design earthquake level SL-2), the tensile strain at some concrete monitoring points near the fixed bottom of the model reached cracking level. The equivalent lateral stiffness of the model is decreased by 5% of its initial value. When the peak acceleration was 3 g, the maximum principal tensile strains at monitoring points on the cylinder, except the monitoring points near the bottom, were less than the cracking strain. The equivalent lateral stiffness of the model is decreased by 14% of its initial value. The test PCCV model as a whole was within the elastic range. The PCCV with semi-spherical dome has sufficient seismic resisting safety.