A lift-off revision method for magnetic flux leakage measurement signal

Lisha Peng,Songling Huang,Shen Wang,Wei Zhao
DOI: https://doi.org/10.1109/I2MTC.2018.8409535
2018-01-01
Abstract:Magnetic flux leakage (MFL) measurement technique is commonly used in oil and gas pipeline integrity detection and defect estimation. Subject to the measurement condition, the lift-off effect is unavoidable which will affect the strength and trend of MFL signal seriously. In order to weaken the lift-off effect, this paper proposed a lift-off revision method to revise the measured signal down to a considerable level. Firstly, two corresponding signals at different lift-offs are measured. Then the signals are revised by a lift-off revision formula which is deduced based on the trend and depth-combination property of MFL signal. To demonstrate the feasibility and accuracy of the proposed method, the lift-off is revised not only from the simulation signals, but also from the experimental data of an artificial corrosion defect. In both cases, the proposed method shows a good performance for the lift-off revision of MFL signal.
What problem does this paper attempt to address?