A Simplified Lift-Off Correction for Three Components of the Magnetic Flux Leakage Signal for Defect Detection

Lisha Peng,Songling Huang,Shen Wang,Wei Zhao
DOI: https://doi.org/10.1109/tim.2021.3058407
IF: 5.6
2021-01-01
IEEE Transactions on Instrumentation and Measurement
Abstract:Magnetic flux leakage (MFL) testing is widely used to detect and estimate defect in ferromagnetic materials. The lift-off of sensors caused the weakening of the detected signal inevitably. Therefore, it is necessary to correct lift-off for the detected MFL signal. In this article, we analyze the approximate negative exponential relationship between the three components of MFL signal of the defect and the lift-off based on magnetic dipole analytical method and establish a simplified numerical calculation model of MFL signal based on the lift-off. A lift-off correction method is also proposed to revise the three components of the MFL signal at a suitable range of lift-off efficiently. In this method, an exponential function compensation is introduced and only the lift-off correction value is concerned. The validity of the correction method is verified by the 3-D MFL testing experiment for the ferromagnetic pipeline defects. The results demonstrate that the corrected MFL signals match the experimental signals well.
engineering, electrical & electronic,instruments & instrumentation
What problem does this paper attempt to address?
### Problems the Paper Attempts to Solve This paper aims to address the issue of the impact of the distance between the sensor and the surface of the sample being tested (i.e., lift-off distance) on the detection signal in Magnetic Flux Leakage (MFL) testing. Specifically: 1. **Background and Problem**: - Magnetic Flux Leakage (MFL) testing is an electromagnetic non-destructive testing technique widely used to detect defects in ferromagnetic materials. - The presence of lift-off distance leads to a weakening of the detection signal, thereby affecting the detection effectiveness. - Variations in lift-off distance under different testing conditions affect the consistency of the signal. 2. **Objectives**: - To establish a simplified mathematical model to reveal the approximate negative exponential relationship between the defect MFL signal and the lift-off distance. - To propose a simplified method to correct the impact of lift-off distance on the MFL signal within a certain range. - To experimentally verify the effectiveness of the proposed method. 3. **Main Contributions**: - Analyzed the approximate negative exponential relationship between the three components of the defect MFL signal and their lift-off distances. - Established a simplified MFL signal calculation model based on lift-off distance. - Proposed a simplified method to correct the MFL signal lift-off distance within a reasonable range. - Experimentally verified the effectiveness of the proposed method and demonstrated that the corrected MFL signal matches well with the experimental signal.