Abstract:In this paper, a partial discharge location technique based on double helix ultrasonic sensor array is proposed, and its accuracy has been verified by simulation. Firstly, the paper introduces the double helix array and the location algorithm; Secondly, LMS Virtual Lab is used to establish an acoustic finite element model. This model simulates an ultrasonic single narrowband PD source, and the double helix sensor array is also simulated to collect the ultrasonic signals emitted from the source. Next, combined with the frequency response curve of the sensor, the signal received by the array is processed, including Fourier transform and inverse Fourier transform and so on. Finally, the signal is imported to MUSIC algorithm to draw the corresponding spatial spectrum. From the spatial spectrum, the direction angle and pitch angle of the PD source can be obtained, which means the PD source can be located. Based on simulation, the result shows that the accuracy error of ultrasonic positioning based on double spiral ultrasonic sensor array is less than 7%. It means that this array can successfully locate the PD source, and can also meet the requirements of engineering application.