Effects of Orientation and Structure Geometry on Boiling Heat Transfer for Downward Facing IGTAC Surfaces

Dawen Zhong,Jun Sun,Ji'an Meng,Zhixin Li
DOI: https://doi.org/10.1016/j.ijheatmasstransfer.2018.03.007
IF: 5.2
2018-01-01
International Journal of Heat and Mass Transfer
Abstract:External Reactor Vessel Cooling has been a key severe accident management strategy to prevent the damage of the reactor vessel. Saturated pool boiling heat transfer coefficients and critical heat flux (CHF) were measured from the downward facing structured surface of interconnected-grooves with triangular array cavities (IGTAC surface) in deionized water to enhance the CHF. Four IGTAC surfaces were investigated at inclination angles of 5 degrees, 30 degrees, 45 degrees, 60 degrees and 90 degrees (vertical). The experimental results indicated that the CHF increases with the increasing inclination angle. The highest CHF at inclination angle of 5 degrees on downward facing IGTAC surface could reach 1258.4 kW/m(2), which was over 2 times of that on a plain surface. The CHF on IGTAC surface did not appear at larger inclination angles when the heat flux reached 2400 kW/m(2), which is the limit of the experimental apparatus. The IGTAC surfaces can form a liquid-vapor conversion path with the cavities as stable nucleation sites and the interconnected grooves as the cooling water supply pathways, which results in a significant boiling heat transfer enhancement and CHF increase. It is shown that deeper groove depth and larger cavity diameter will enhance the nucleate boiling heat transfer (NBHT) and CHF on IGTAC surfaces within the current dimension parameter range. (C) 2018 Elsevier Ltd. All rights reserved.
What problem does this paper attempt to address?