Fiber Bragg grating sensor for magentic field measurement

Rui Ma,Wentao Zhang,Zhaogang Wang,Wenzhu Huang,Fang Li,Dongmei Li
DOI: https://doi.org/10.1109/icsens.2017.8233969
2017-01-01
Abstract:This paper proposed a novel static magnetic field sensor which integrates a Terfenol-D rod with a Fiber Bragg grating Fabry-Perot(FBG-FP) cavity. In order to improve the performance of the sensor, a theoretical model about pre-stress and the magnetic field sensitivity is established. And the correctness of the model is verified by experiments. The experimental results show that the sensor has good linearity in response to static magnetic field. The sensitivity of the sensor is 5×10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-4</sup> pm/μT when the value of pre-stress is 3 MPa.
What problem does this paper attempt to address?