Building Energy Assessment Based on a Sequential Sensitivity Analysis Approach

Wei Tian,Yunliang Liu,Jian Zuo,Baoquan Yin,Yu Sun,Xing Fu,Xianhao Meng
DOI: https://doi.org/10.1016/j.proeng.2017.10.168
2017-01-01
Procedia Engineering
Abstract:Sensitivity analysis has been widely used in building energy assessment to provide reliable analysis of importance ranking for input variables in buildings. Most of previous studies used one single batch simulation models to obtain sensitivity indicators. To conduct robust analysis, this paper implements a sequential sensitivity analysis to assess the convergence of sensitivity indicators for two global sampling-based sensitivity analysis methods (standardized regression coefficients and meta-modelling Sobol) in an office building. The results indicate that this sequential method can be more effective and robust. In contrast, a single batch sensitivity method for building energy assessment may lead to non-convergence results due to smaller number of simulation models or over-convergence results due to larger number of simulation models. It is also found that the convergence rate for standardized regression methods are slower than that for the meta-modelling Sobol method.
What problem does this paper attempt to address?