Novel Sample Preparation and High-Resolution X-ray Tomography for Package FA

Christian Schmidt,Stephen T. Kelly,Ying Wang,S. T. Coyle,Michael Hassel Shearer
DOI: https://doi.org/10.1109/ipfa.2017.8060174
2017-01-01
Abstract:In this study, we introduce high-resolution X-ray tomography into the daily failure analysis (FA) work flow for semiconductor packages. Two application cases, the investigation of Back-end of line (BEOL) and μ-bump features have been selected to demonstrate its advantage. The paper focuses on a feasibility study for different measurement parameters and proposes an advanced FA flow including newly-developed sample I preparation based on ps-laser excitation.
What problem does this paper attempt to address?