Nanosecond pulsed dielectric barrier discharge plasma-catalytic removal of HCHO in humid air

Shuai Zhang,Wenchun Wang,Li Zhang,Zilu Zhao,De-Zheng Yang
DOI: https://doi.org/10.1051/epjap/2017160361
2017-01-01
Abstract:Non-thermal plasma (NTP) has been regarded as a promising method for the removal of a wide range of low concentration volatile organic compounds (VOCs). In this paper, nanosecond pulsed and alternating current dielectric barrier discharge plasmas synergistic catalyst are utilized for removal of formaldehyde (HCHO) in humid air. Working gas is 1% H2O/21% O-2/78% N-2 with 154 ppm HCHO over total flow rate of 50 mL/min. Specific energy density (SED) are 32.5 JL(-1), 35.8 JL(-1) and 1069.2 JL(-1) at power consumption of 0.325 W, 0.3 W, 8.9 W for removal of 67%, 63.8% and 73.8% HCHO when using bipolar nanosecond pulsed, unipolar nanosecond pulsed and AC dielectric barrier discharge (DBD) plasma, respectively. The removal efficiencies of HCHO using nanosecond pulsed DBD plasma increase approximately 10 similar to 20% when the packed-bed Al2O3 pellets exist and can reach up to almost 100% when TiO2 nanoparticles are used while the effect of CeO2 nanoparticles is a bit poor. Analysis indicate that OH radical and O atom play main role for removal HCHO and the gas temperature is a significant factor for its influence on rate constants of HCHO with active particles.
What problem does this paper attempt to address?