Calorimetric Power Measurements in the EAST ECRH System

Weiye Xu,Handong Xu,Fukun Liu,Jian Wang,Xiaojie Wang,Yongzhong Hou
DOI: https://doi.org/10.1088/2058-6272/aa7ec9
2017-01-01
Abstract:In this paper, the calorimetric power measurement method for electron cyclotron resonance heating system on EAST are presented. This method requires measurement of the water flow through the cooling circuits and the input and output water temperatures in each cooling circuit. Usually, the inlet water temperature is controlled to be stable to get more accurate results. The influence of the inlet water temperature change on the measurement results is analyzed for the first time in this paper. A novel temperature calibration method is proposed also. This kind of calibration method is accurate and effective, and can be easily implemented.
What problem does this paper attempt to address?