Analysis of loss of residual heat removal system for CPR1000 under cold shutdown operation

Junli Gou,Haifu Ma,Zijiang Yang,Jianqiang Shan
DOI: https://doi.org/10.1016/j.anucene.2017.03.004
IF: 1.9
2017-01-01
Annals of Nuclear Energy
Abstract:•Transient behaviors of CPR1000 under cold shutdown conditions are simulated.•The starting time of coolant boiling highly depends on the water inventory in the RPV.•The starting time of core uncovering highly depends on the plant configurations.•The results can provide guideline for an operator to strategize a mitigation action.
What problem does this paper attempt to address?