A zero-sequence voltage injection control scheme for modular multilevel converter under submodule failure

Jinke Li,Xuezhi Wu,Xiuyuan Yao,Long Jing,Xinmin Jin,Wen Wu,Xiaoxing Wang,Shuai Wang
DOI: https://doi.org/10.1109/ECCE.2016.7854809
2016-01-01
Abstract:In this paper, a modulation strategy based on zero-sequence voltage injection is proposed for module multilevel converter (MMC). By the proposed method, the remaining capacitor voltages not vary and the line-to-line voltages are balanced. This method is easy to be implemented by adjusting the voltage injection coefficient when SM fault occurs. The coefficient of injected zero-sequence voltage is designed by the number and position of the fault submodules (SMs) and the fault-tolerant capability of this method are also discussed. The effectiveness and advantages of proposed method are confirmed with simulation and experiment.
What problem does this paper attempt to address?