Optimization of Geosmin Removal from Drinking Water Using Uv/H2o2

Fengxun Tan,Haihan Chen,Daoji Wu,Ning Wang,Zhimin Gao,Lin Wang
DOI: https://doi.org/10.12783/issn.1544-8053/13/1/4
2016-01-01
Abstract:Geosmin (GSM) is a common odor-causing compound in drinking water with a low odor threshold (10 ng/L). Since conventional treatment processes cannot effectively remove it, both laboratory experiments and pilot trials were performed in this study to evaluate UV/H2O2 advanced oxidation process in GSM removal from drinking water. Results demonstrated removal efficiency of GSM increased with an increase in H2O2 concentration. GSM was reduced from 582 ng/L to below the detection limit (5 ng/L) after 8 min of reaction with 3.92 mg/L of H2O2. GSM was reduced from 514 ng/L to 8 ng/L after 8 min of reaction with 1.93 mg/L of H2O2. Degradation of GSM conformed to first-order kinetics. Data obtained from pilot trials were analyzed with Design-Expert software and optimal operation conditions were determined (H2O2 concentration of 7.5 mg/L, UV intensity of 400 mJ/cm(2), and GSM concentration of 300 ng/L) for the highest GSM removal percentage of 97.14%. Reaction rate between UV/H2O2 and GSM was determined using the same software fitting experimental data.