Characterization of Electromagnetic Pulses Via Arrays on Shenguang-Iii Laser Facility Laser

Ming Yang,Tingshuai Li,Chuanke Wang,Jinwen Yang,Weiming Yang,Tao Yi,Shenye Liu,Shaoen Jiang,Yongkun Ding
DOI: https://doi.org/10.3788/col201614.101402
IF: 2.56
2016-01-01
Chinese Optics Letters
Abstract:Intensive electromagnetic pulses ( EMPs) can be generated from interaction of the ultra-intense lasers and solid targets in inertial confinement fusion ( ICF), which will detrimentally affect the data acquisition from some electric components. A diagnostic system for EMP measurement inside and outside the ShenGuang-III facility is designed and fabricated in this study. The experimental results indicate that the peak magnitude of EMP reaches up to 3210.7 kV/m and 6.02 T. The received signals depend most on the antenna and target types. The half-hohlraum generates a more intensive EMP radiation than that from the other targets, and the large planar and medium discone capture much stronger signals than the other antennas. In addition, the mechanisms of EMP generation from different targets are discussed. The resulting conclusion are expected to provide the experimental basis for further EMP shielding design.
What problem does this paper attempt to address?