A self-recalibration method based on scale-invariant registration for structured light measurement systems

Rui Chen,Song Zhang,Heping Chen,Yong Guan,Ken Chen
DOI: https://doi.org/10.1016/j.optlaseng.2016.07.003
IF: 5.666
2017-01-01
Optics and Lasers in Engineering
Abstract:The accuracy of structured light measurement depends on delicate offline calibration. However, in some practical applications, the system is supposed to be reconfigured so frequently to track the target that an online calibration is required. To this end, this paper proposes a rapid and autonomous self-recalibration method. For the proposed method, first, the rotation matrix and the normalized translation vector are attained from the fundamental matrix; second, the scale factor is acquired based on scale-invariant registration such that the actual translation vector is obtained. Experiments have been conducted to verify the effectiveness of our proposed method and the results indicate a high degree of accuracy.
What problem does this paper attempt to address?