Detection of Total Biogenic Amines in Foods by Chemiluminescence Biosensor
Han TANG,Xiao-Peng WANG,Zhong-Bo WU,De-Hui WAN,Xiao-Yu LIU
2014-01-01
Abstract:Objective To establish a method for the analysis of the biogenic amines content in foods. Methods A novel micro-fluidic chip-chemiluminescence-enzyme biosensor was designed and assembled to determine the total biogenic amines content in foods. Commercial diamine oxidase was used as biological recognition element of the sensor, the micro-fluidic chip with chemiluminescence analyzer was used as a sensing element, and luminol-ferricyanide was used in chemiluminescence system. Results When the concentration of putrescine, histamine, and tyramine were 3~500, 2~100, 3~200 μmol/L, the linear regression equation were Y=17.448X+408.93, Y=88.329X+997.13, Y=45.762X+1728.2, the correlation coefficient were 0.9966, 0.9937, 0.9907, and the detection limit were 0.7, 0.5, 0.5 μmol/L, respectively. In addition, this study evaluated the performance of the sensor. Under optimal conditions, putrescine, histamine, tyramine solutionwere measured, the RSD were between 90%~94%(n=7), the precision was good; when chosing putrescine as substrate, luminol and potassium ferricyanide was entered into chemiluminescence analyzer for seven times, the RSD=1.66%, stability was good; The immobilized enzyme was stored in phosphate buffer, measured every 10 d, lasting 70 d. The activity of immobilized diamine oxidase reduced by 15% in 2 months. Using this sensor to detect the total amount of biogenic amines in pork, fish and red wine, all three recoveries of amine were more than 89%. Conclusion This sensor has good performance, and it can be used for rapid detection of biogenic amines in foods.