Abstract:This paper describes a soft starting control strategy for synchronous motors fed by load-commutated inverters (LCI). At low speed, high frequency (HF) current injection method is employed to obtain rotor position. When the motor speed reaches 5% of the rated motor speed, zero-crossing detection of back electromotive force (EMF) is adopted to monitor rotor position. According to the rotor position, SCRs can exactly be triggered at the right time to regulate inverter. Meanwhile, there is a transition between forced commutation mode at low speed and load commutation mode at medium and high speed. Then the soft start of synchronous motor, namely motor operates from standstill to rated speed, and grid-connection without negative impacts can be realized finally. The feasibility of the proposed control strategy is validated on a 15kW LCI-fed synchronous motor.