Effect of Ultrasonic Parameters on Bonding Quality of Rolled T2 Copper Foil and Au Wire

Peng Zhang,Qiang Zhu,Gang Chen,Dong Luan,Chuanjie Wang
DOI: https://doi.org/10.1080/10584587.2016.1169786
2016-01-01
Integrated Ferroelectrics
Abstract:In this paper the effect of ultrasonic parameters on ball bonding quality of T2 copper foil and gold wire was investigated experimentally. The results indicate that a better bonding quality was obtained under the ultrasonic power range from 185 mw to 195 mw and the ultrasonic time range from 160 ms to 180 ms. Both the positive and negative effects of ultrasonic power lead to the fluctuation of bonding quality. Ultrasonic time was the factor which intensified the bonding effect whose influence was less obvious. Through the analysis of morphology of bonding joint and bonding section, bonding joint was composed of rim flashes, bonding area and residual tail wire, bonding specimens were well bonded for the radial resistance of streamlines. This was different to conventional bonding process that the central bonding region of which usually appeared unbonded area.