The Sterilization Application of a Series of TiO2 Catalysts Catalyzed by Ultrasonic Wave in Killing Bacteria

王君,李铁民,韩建涛,陈长兰,赵迪
DOI: https://doi.org/10.3969/j.issn.1001-5914.2004.06.015
2004-01-01
Abstract:Objective To study the sterilization of a series of TiO2 catalysts catalyzed by ultrasonic wave. Methods Added common TiO2, nanometer TiO2 and WO3 doped nanometer TiO2 to the medium (colibacillus 106 cfu/ml ) followed by exposure to the experiments of ultrasonic (25 kHz, 50W ) for 75 min, then observed the effect of exposure time, medium acidity, particle diameter and dosages of TiO2 catalysts on the sterilization. Results Killing bacteria were carried out on the series of TiO2 catalysts including common TiO2, nanometer TiO2 and WO3 doped nanometer TiO2 and their capabilities of killing bacteria were compared one another. The experimental results showed that these catalysts had the obvious function of killing Colibacillus under ultrasonic irradiation. The efficiency of killing bacteria reached about near to 100% for the bacteria density liquid of 106 cfu/ml when the experimental conditions are 1.0 mg/ml concentration of the series of TiO2 catalyst was 1.0 mg/ml, pH=3.0, ultrasonic irradiation (25 kHz, of 50 W) for input power and 25 kHz frequency and 60 min irradiation. As for exposed for 75 min, the efficiency of killing bacteria ranked as follows: but it is known that the order of the effect of killing bacteria is WO3 doped nanometer TiO2 nanometer TiO2 common TiO2 by the comparison of these catalysts. Conclusion Catalysed by ultrasonic wave, a series of TiO2 catalysts will show a significant effect of killing colibacillus.
What problem does this paper attempt to address?