Investigation on the Accuracy of Flame Height Relation Model for Crude Oil Pool Fire

Shan-shan LI,Jian-gang SUN,Zhen WANG,Nan-nan WANG,Li-fu CUI
DOI: https://doi.org/10.3969/j.issn.1009-315X.2014.03.015
2014-01-01
Abstract:Experiments were carried out on the flame heights of crude oil pool fires with different pool diameters of 1. 5, 2, 3 and 5 m in daqing oil field, and the experimental values of flame height were compared with the calculated values by the relation models. The results show that the values of flame height calculated by the Thomas relation model agree well with the experi-mental data at the pool diameters of 1. 5 m and 2 m, but have a great deviation at the pool diam-eters of 3 m and 5 m. Also the Thomas relation model is corrected based on the experimental re-sults.
What problem does this paper attempt to address?