The Research on Reliability of Inversion Switch for Electronic Piezo Gauge

HU Xiangnan,ZU Jing,ZHANG Yu,HUANG Hui
DOI: https://doi.org/10.3969/j.issn.1005-9490.2014.06.011
2014-01-01
Abstract:Due to the complex working condition of electronic piezo gauge,the inversion switch makes the electronic piezo gauge sometimes fail in power-on or sometimes makes a mistake falsify in power-on. To guarantee electronic piezo gauge could be in power-on normally,a method to study the reliability of inversion switch was designed by using reliability testing system, Marshall’s impact hammer and quantitative calculation, and a set of inversion switches was analysed specifically by using this method. The study of reliability provides an important guarantee for the success of gun chamber pressure test.
What problem does this paper attempt to address?