Evaluation of Stricture after Biliary Surgery by Radionuclide Hepatobiliary Dynamic Imaging

金常青,于建芳,丁慈德,余永利,陆汉魁,朱瑞森
DOI: https://doi.org/10.3321/j.issn:1003-3289.2004.z2.049
2004-01-01
Abstract:Objective To investigate the value of radionuclide hepatobiliary dynamic imaging in diagnosing stricture after biliary surgery. Methods 13 cases of patients with biliary surgery and 15 cases for normal control received 99m Tc-EHIDA dynamic imaging. The peak time,1/4 and 1/2 excretory time of liver, gallbladder and duodenum were respectively calculated. Results The excretory curve of patients with stricture after biliary surgery declined slowly and that of patients with atresia after biliary surgery was flat. 1/4 and 1/2 excretory time of stricture patients can't be calculated while duodenum image of atresia patient can't be seen. Distinct difference exist between stricture patients and normal person. Conclusion Analysis of activity verse time curve of biliary dynamic imaging is valuable to determine stricture after biliary surgery.
What problem does this paper attempt to address?