Improvement of detection limit in HPLC determination of galantamine in plasma

司天梅,孙丽丽,舒良,张鸿燕
DOI: https://doi.org/10.3321/j.issn:1003-3734.2003.10.017
2003-01-01
Abstract:Objective:To improve the detection limit in HPLC determination of galantamine in plasma. Methods:The alkalized plasma sample was extracted with absolute ether for twice, combined the extracts, after evaporation of ether the residue was dissolved by mobile phase with dissolved atenolol reference standard. After treatment,the sample was injected into the hypersil-C8 reverse phase column. The mobile phase consisted of acetonitrile-H2O (30:70) with 0.2% triethylamine and its pH was adjust to 5.9 with HAC,and the fluorescence detector was set as follows;EX 290nm and EM 320nm. Results : A liner range of 1 - 50μg · L -1 ( r = 0. 999) ,a minimum detectable limit of 0. 2ng, a minimum detectable concentration of 1μg·L-1, a recovery of 80% were obtained in this analysis. The intra-day and inter-day RSD were less than 11.86% and 8.4% respectively. Conclusion: A sensitive and accurate method suitable for clinical monitoring of plasma galantamine hydrobromide concentration is developed.
What problem does this paper attempt to address?