Unstable femoral periprosthetic fractures treated with a modular long-stem prosthesis

Yuanqing MAO,Jiawei XU,Jingwei ZHANG,Huiwu LI,Zhen'an ZHU
DOI: https://doi.org/10.3969/j.issn.2095-9958.2015.05-07
2015-01-01
Abstract:Background:There is no unified treatment for unstable femoral periprosthetic fractures at present, especially those with se-vere bone defects. <br> Objective:To evaluate the effect of modular long-stem prosthesis in treating unstable femoral periprosthetic fractures. <br> Methods:Twenty-five consecutive patients with unstable femoral periprosthetic fractures were treated by using a modular long-stem prosthesis. The joint function was assessed by Harris hip score (HHS). The fracture healing, prosthetic loosening and bone defect repair were evaluated by X-rays. <br> Results:The mean duration of follow-up was (44.0±16.2) months (range, 12-84 months) in all the patients. The mean preop-erative HHS was 22.3±6.2 (range, 7-31), which was significantly lower than that at the last follow-up (85.2±5.0, ranging, 70-91, P<0.01). All fractures were healed. No prosthetic loosening or refracture occurred. There was one hip dislocation and one periprosthetic infection after surgery. <br> Conclusions:The modular long-stem prosthesis is a very good clinical option in treating unstable femoral periprosthetic frac-tures for convenient operation, satisfactory outcomes and low complication rate.
What problem does this paper attempt to address?