Indirect Position Control of High Speed Switched Reluctance Motor

MA Qing-qing,GE Bao-ming,BI Da-qiang,LI Shuo
DOI: https://doi.org/10.3969/j.issn.1007-449x.2014.11.001
2014-01-01
Abstract:Turn-on angle and turn-off angle are not flexibly and precisely controlled,which limits the motor efficiency and performance at high speed. Sensorless position detection strategy was proposed with adjusting switched angle in real-time according to different speed. Flux linkage models at different positions were calculated by using the FE model. In order to improve angle position control precision,the principle of selecting reference flux linkage was presented based on characteristics of flux linkage model of SRM.On this basis,the angular position control of SRM was implemented by adjusting turn-on and turn-off angle in real-time at different speed. To verify the validity of the sensorless position detection strategy,a low-speed and high-speed prototype were used. The tests verify that proposed control strategy is suitable for low-speed and high-speed SRM and rotor position estimation precision is high.
What problem does this paper attempt to address?