Glutaraldehyde Modified Gold Electrode for Subsequent Histidine Attachment and Determination of Copper

李昌安,葛存旺,刘战辉,张海黔,顾宁
DOI: https://doi.org/10.3969/j.issn.1004-1699.2003.04.023
2003-01-01
Abstract:A new chemically modified gold electrode was prepared by Glutaralhehyde modified electrode for subsequent histidine attachment. A new approach was developed for sensitive and selective determination of copper by the electrode. A complex of copper with the modifier was formed and accumulated on surface of the electrode while immersed the electrode into a copper-containing solution. In a NaH 2PO 4-Na 2HPO 4buffer solution (pH6.8), the electrode has good electro activity. While adding copper,the current increase and the potential remains same. The value of peak current is linear with the copper concentration in ranges 1×10 -12~1.8×10 -11 mol/L and 5×10 -7~2.1×10 -5 mol/L. The detection limits is 0.5 pmol/L and an indirect mechanism of determination is proposed.
What problem does this paper attempt to address?