Contradistinction of Cold Modeling Tests and Hot Modeling Test for Gas Flow in T-Fired Furnace

周屈兰,窦文宇,徐通模,惠世恩
DOI: https://doi.org/10.3321/j.issn:1000-6761.2003.03.007
2003-01-01
Abstract:The flow characteristics in T fired furnace is studied by cold modeling test and hot modeling test. Some conclusions are drawn as:①diameter of actual tangential circle in hot condition is larger than that of cold condition; ② moment of momentum flux of gas flow in furnce decreases along height of furnace, and decreases faster in hot condition than in cold condition; ③opposing tangential circle of primary air may effectively decrease moment of momentum flux in furnace and obviously alienate to residual rotation at exit of furnace. Figs 8, table 1 and refs 3.
What problem does this paper attempt to address?