Determination of the Content of Puerarin in Zhonghuang Capsules with RP- HPLC

童荣生,席庆,孙世明,吴正中
DOI: https://doi.org/10.3969/j.issn.1001-0408.2002.06.028
2002-01-01
Abstract:OBJECTIVE:To establish a RP-HPLC method for the determination of the content of puerarin in Zhonghuang capsules to control the quality of the product METHODS:The determination was performed on a Diamonsil C18 column(5μm,150mm×4 6mm) by UV detector at 249nm with methanol-0 015% phosphorate acid(23∶77) as the mobile phase at a flow rate of 1 2ml/min RESULTS:The calibration cure was linear in the range from 0 020μg to 0 120μg of puerarin(r=0 9 999) The average recovery and the relative standard deviation of puerarin were 98 54% and 1 07%(n=6),respectively CONCLUSION:The method is simple,accurate and reliable and can be used for the quality control of Zhonghuang capsules