Stress Analysis of the Denture Support Structure on Mandibular Titanium Framework

孙健,张富强,张秀娟,王冬梅
DOI: https://doi.org/10.3969/j.issn.1009-3761.2004.04.021
2004-01-01
Abstract:Objective: To analyze the design of the denture support structure on Mandibular titanium framework.Methods: The finite element model of Mandibular titanium framework with hollow on the position of correspondingmissing teeth was establoshed. Different designs of the denture support structure on Mandibular titanium framework wereanalysed under various loadings. Results: The most concentrate area of stress was the neck of abutment. As for the wholetitanium framework, the value of the stress was low and symmetric. The stress in the neck of abutment decreased significantlywith the increase of the diameter of the hollow, while the ratio of the height of the abutment to the length of the hollow hadno effect on the stress. Conclusions: 2mm of the diameter of the hollow with 0.5mm on its peripheral area are suitable foranterior teeth missing, while 4mm (0.5mm) are suitable for posterior teeth missing. With the assurance of the strength ofthe screw, the length of the hollow should be decreased auording to possible as you can. And the whole titanium systemshould be designed as the style of framework.
What problem does this paper attempt to address?