A Preliminary Study on Modified Gold Ring Implantation Through Anterior Chamber Angle in Rabbit

郭文毅,孙兴怀,钱韶红,褚仁远,金晓红,余晓波,陈荣家
DOI: https://doi.org/10.3969/j.issn.1671-2420.2003.02.003
2003-01-01
Abstract:Purpose To investigate the efficacy of modified gold ring implantation through anterior chamber angle on reduction of intraocular pressure(IOP) and histopathologic response in normal rabbit eyes. Methods 14 eyes of 8 albino rabbits underwent gold ring implantation through anterior chamber angle. Slit-lamp examination and tonometry were done after operation. Histopathologic changes were studied 2 months and 3 months postoperatively. Results The filtering bulb was good in the early postoperative period. The bulb lasted 19.57 ± 19.55 days. 14 rabbit eyes achieved a significant reduction of IOP from preoperative 19.71 ± 1.94 mmHg to postoperative 13.71±3.65 mmHg (one day later) ,15.50±3.46 mmHg(one week later) and 17. 57 ± 3. 35 mmHg (two months later) respectively. There was not a significant difference between the postoperative IOP level on three months later (18.88 ± 1.75 mmHg) and the baseline in 8 eyes. The slit-lamp examination indicated the slighter tissue response. The histopathologic changes were similar in three kinds of gold ring. The hole with pseudomembraneous inner wall existed in the tissue of comeoscleral limbus. There were more fibroblasts and fewer lymphocytes and macrophages around the outer wall of hole. No significant inflammation was observed. Conclusion It is suggested that modified gold ring implantation through anterior chamber angle is effective to lower the IOP in rabbits with slight tissue response.