The Effect of Intraocular Pressure Fluctuation During LASIK on Rabbit Optic Nerve Axons

周浩,褚仁远,周行涛,戴锦晖,孔祥梅
DOI: https://doi.org/10.3760/cma.j.issn.1674-845x.2003.03.003
2003-01-01
Abstract:Objective:LASIK has been widely performed in treating myopia and most operators are unaware of its potential risk to optic nerve fiber. The purpose of the study was to determine quantitatively the effect of intraocular pressure fluctuation during LASEK on rabbit optic nerve axons and evaluate the safety of LASK. Methods: 33 New Zealand white rabbits were divided into regular vacuum group, high vacuum group and ultra-high vacuum group randomly . Different value of vacuum pressure was used during the operation and IOP of three groups were elevated to about 60 mmHg, 90 mmHg and 120 mmHg respectively. After 6 weeks the eyes were enucleated and 1μm cross-sections were made staining with toluidine blue. Photography was taken under light microscope and a computer image analysis system was used to count the optic nerve axons.Results:The optic nerve axon number of control eyes and surgical eyes was 98194±10282, 96151± 11500(regular vacuum group); 92434±10795,89069±8916(high vacuum group), 94071±9348,80953±11548 ( ultra-high vacuum group) respectively. The optic nerve axons of surgical eyes in ultra-high vacuum group are less than the controls( P 0.01). In the other two groups, there are no significant difference between surgical eyes and controls(P 0.05). Conclusion: During the LASK, high vacuum suction could be dangerous for eyes. Unphysiologic high IOP flunctuation in a short moment can cause damage to the optic nerve axons.
What problem does this paper attempt to address?