Experimental study on flow rate measurement method based on control valves

Xiaolei TAO,Xiaodong ZHAO,Jun WU,Yuan LIAO
DOI: https://doi.org/10.3969/j.issn.1004-1540.2014.02.006
2014-01-01
Abstract:A new flow rate measurement method based on control valves was proposed.With the inherent characteristic flow curve of control valves and the differential pressure between upstream and downstream,the flow rate could be acquired.Experimental study was conducted to obtain the pressure sampling sites arrangement principle that the upstream point was close to the valve and the downstream point was relatively far away.Steady flow experiment showed that larger differential pressure and smaller valve opening came with better measurement accuracy.Unsteady flow experiment showed that both the sinusoidal signal and random signal valve core movement have good measurement accuracy and the main source of errors included the valve core fast movement and the valve core reversion.
What problem does this paper attempt to address?