Pilot-scale experiment on anaerobic bioreactor landfills in China.
Jianguo Jiang,Guodong Yang,Zhou Deng,Yunfeng Huang,Zhonglin Huang,Xiangming Feng,Shengyong Zhou,Chaoping Zhang
DOI: https://doi.org/10.1016/j.wasman.2006.07.008
IF: 8.816
2007-01-01
Waste Management
Abstract:Developing countries have begun to investigate bioreactor landfills for municipal solid waste management. This paper describes the impacts of leachate recirculation and recirculation loadings on waste stabilization, landfill gas (LFG) generation and leachate characteristics. Four simulated anaerobic columns, R1–R4, were each filled with about 30tons of waste and recirculated weekly with 1.6, 0.8 and 0.2m3 leachate and 0.1m3 tap water. The results indicated that the chemical oxygen demand (COD) half-time of leachate from R1 was about 180 days, which was 8–14 weeks shorter than that of R2–R4. A large amount of LFG was first produced in R1, and its generation rate was positively correlated to the COD or volatile fatty acid concentrations of influent leachates after the 30th week. By the 50th week of recirculation, the waste in R1 was more stabilized, with 931.2kg COD or 175.6kg total organic carbon released and with the highest landfill gas production. However, this contributed mainly to washout by leachate, which also resulted in the reduction of LFG generation potential and accumulation of ammonia and/or phosphorus in the early stage. Therefore, the regimes of leachate recirculation should be adjusted to the phases of waste stabilization to enhance efficiency of energy recovery. Integrated with the strategy of in situ leachate management, extra pre-treatment or post-treatment methods to remove the nutrients are recommended.