Effect of Plating Parameters on Plating Rate and Thickness As Well As Surface Morphology of Electroless Tin Coating
徐磊,何捍卫,周科朝,刘洪江
DOI: https://doi.org/10.16577/j.cnki.42-1215/tb.2009.05.019
2009-01-01
Abstract:In order to realize continuous tin electroless plating and increase the deposition rate, a new method was established. The effects of plating parameters (such as bath composition, pH val-ue, temperature, plating time, and stirring rate) on the surface morphology and thickness of the coating were investigated by means of scanning electron microscopy (SEM) , X-ray diffraction (XRD) , energy dispersive spectrometry (EDX) , and chemical analysis. Results show that the optimal temperature and pH value for tin electroless plating were determined to be 80~ 85 ℃ and 0.6 ~0.8, and the optimized bath was composed of 20.0~25.0 g/L SnCl2, 70. 0 ~ 75. 0 g/L ( NH2 )2 CS, 70.0 ~ 75. 0 g/L NaH2P02 ? 2H2 0, 75. 0 ~ 80. 0 g/L H2SO4, 5. 0~ 8. 0 g/L CH4O3S,5.0~8.0g/L EDTA, 2.0~4.0g/L C6H6O2, 10.0~15.0 g/L C2H6O2, 0.5 ~1.0 g/L H3P04, 0.5 -1.0 mL/L HCHO, and 1.0 g/L OP-10. Using the established tech-nology, it was feasible to conduct continuous tin electroless plat-ing, and the thickness of the coating after 3 hour of continuous plating was as much as 32.72 μm.