T shape locking compression plate fixation of intra-articular fractures of distal radius

卢华定,蔡道章,王昆,王其友
DOI: https://doi.org/10.3969/j.issn.1005-8478.2004.23.018
2004-01-01
Abstract:Objective:To study the clinical outcomes of treatment using T shape locking compression plate in comminuted and intra-articular fractures of distal radius.Method:Sixteen cases of distal radial fractures were treated with open reduction and internal fixation with T shape locking compression plate,and got early functional exercises postoperatively.Result:All the patients were followed up for 7 to 15 months with an average of 10 months.Union was obtained in all the patients.The clinical outcomes was evaluated according to modified McBride grading.Fourteen cases were graded as excellent and 2 as good.No complication was found.The overall satisfactory rate was 100%.Conclusion: T shape locking compression plate has been proven as a safe and effective implant for treatment of fractures of the distal radius.It is especially suitable for patients with osteoporosis and unstable fractures of the distal radius,in that it can firmly hold the reduced fracture segments and facilitate early postoperative rehabilitation.
What problem does this paper attempt to address?