Combined with implantment of the artificial bone into bone defects through dorsal approach Volar locking compression plate fixation for dorsaly displaced fractures of distal radius

孙玉福,胡茂忠,井万里,高中玉,许东浩,姜文学
DOI: https://doi.org/10.3977/j.issn.1005-8478.2011.16.06
2011-01-01
Abstract:[Objective]To investigate the usage and the clinical outcome of volar locking compression plate fixation for dorsaly displaced fractures of distal radius combined with implantment of the artificial bone into bone defects through dorsal approach.[Method]From Aug.2005 to Jan.2010,27 cases with dorsally unstable distal radius fractures were treated with open reduction and internal fixation with T-LCP.This study involved 8 males and 19 females with an average age of 55.6 years(ranged from 50 to 65 years old).According to AO classification:12 cases of type A3,10 cases of type C2,5 cases of type C3,all of them were closed fractures of distal radius.The fractures of 27 cases were fixed with T-LCP by volar approach and combined with implantment of the Osteoinduction Active Material into bone defects through dorsal minimal incusion.Twenty-seven cases were all treated postoperatively with cast immobilization for 2 weeks.[Result] Twenty-seven cases were followed up for 12 to 24 months and the average time was 17.5 months.The X-ray pictures showed that unions had been achieved in all patients and a mean healing time was 8 weeks.Final volar tilt was averaged 10.5°,ulnar tilt 19.5°and radial shortening were ≤2mm.Step-off or gap of the articular surface ≤2mm.The average final volar flexion was 60°,dorsal flexion 55°,ulnar deviation 25.5°,radial deviation 17°,pronation 65.5°and supination 75.5°.Grip strength was 65% of the contralateral side.The functional recovery was achieved from 8 to 30 weeks with an average time of 20.5 weeks after operation.According to Gartland and Werley wrist scoring system,there were 17 excellent,6 good,3 fair and 1 poor results and the satisfactory rate was 85.2%.No complication was found as infection,nonunion,loosing of nails,CTS,medium neuritis and tendon injury.[Conclusion]The volar fixation of LCP for dorsally displaced fractures of distal radius combined with implantment of the artificial bone into bone defects through dorsal approach,as can improve the quality of bone graft,increase bone healing and prevent reduction loss,provides solid fixation to the fractures.Supplemented with appropriate post-operative training satisfactory results can be achieved.
What problem does this paper attempt to address?