2.4 mm volar locking plate in treatment of complex intra-articular fractures of distal radius

Xinyu Huang,Weidong He,Guohua Xu,Mingming Yang,Honghao Xu
DOI: https://doi.org/10.3969/cma.j.issn.1674-134X.2014.03.008
2014-01-01
Abstract:Objective To investigate the method and curative effects of using the 2.4 mm volar locking plate ( locking compression plate ) in the treatment of complex intra-articular fractures of the distal radius.Methods 48 patients, including 20 males and 28 females with fresh distal radius fractures were admitted to our hospital from 2010.02 to 2013.02.The 2.4 mm volar locking compression plates were used during the open reduction and internal fixation operations within two weeks .According to AO classification , 10 cases were type C1, 14 cases were type C2, and 24 cases were type C3.Results In the palmar tilt and radial inclination , there was no statistic significance in the relative length of the radius in the 2.4 mm group compared with the 3.5 mm group.While in the number of the cases with smooth joint surface , there was statistic significance in the 2.4 mm group compared with the 3.5 mm group.The joint flexion was (96.3 °± 12.6 °) , rotation was ( 97.6 °± 13.8°) , and the grip strength was ( 72.3 ±10.6 ) kg.In the visual analogue scale ( VAS ) for the activity pain and the DASH scores , the 2.4 mm group showed statistic significance over the 3.5 mm group.All the fractures were healed including three cases with complications . Conclusion The 2.4 mm locking plate shows better reduction quality in treating the complex intra-articular fractures of the distal radius , which can reduce the postoperative pain and make the recovery much better .
What problem does this paper attempt to address?