The Role of Spiral CT Measurement in the Transpedicular Screw Fixation in Cervical Spine

黄东生,苏培强,马若凡,李春海,彭焰,刘尚礼
DOI: https://doi.org/10.3969/j.issn.1001-165x.2004.02.024
2004-01-01
Abstract:Objective:To measure the linear parameters of the cervical pedicles from CT scan, and probe the necessity of the transpedicular screw fixation according to the axis of the cervical pedicle. Methods:The spiral computed tomography scan (Elscint CT Twin flash) at the section of 1mm of 8 cervical specimens were taken, then the image data were sent to the software (Silicon Graphics O2 working station) to measure the linear parameters of pedicles from C_ 3~7 , and simulate the topography of the cervical pedicle, calculate respectively the inserting angular safe range with and without the consideration of the diameter of the screw. Results:Neglecting the diameter of the screw, the average inserting angular safe range of C_ 3~7 in the transverse plane were 18.68°、 20.41°、22.43°、 22.50°、 27.55°respectively, and27.55°、 30.31°、 27.70°、 29.03°、 34.88° in the sagittal plane respectively; then concerning the diameter of the screw(3.0 mm), the data became 7.25°、 8.58°、 10.98°、 13.09°、 15.49° and 16.35°、 18.69°、 16.40°、 18.26°、 23.13° respectively. Conclusion:The inserting safe range of transpedicular screw fixation in the cervical spine is quite narrow, while transpedicular screw fixation must be strictly operated according to the axis of the pedicle.
What problem does this paper attempt to address?