SURVEY SUBAXIAL CERVICAL VERTEBRAE FOR TRANSPEDICULAR SCREW FIXATION

xijiang qiu,kangping yang,miao liu,jintang wang,xiaowei zhang
2005-01-01
Abstract:Objective In this study, the pedicles of subaxial vertebrae from C3 to C7 were measured to provide some morphometric data for cervical transpedicular screw fixation. Methods 20 dried bone cervical spinal columns (C 3-C 7), pedicle dimensions (pedicle height, width, length), and transverse and sagittal angles of the pedicles were performed with vernier in linear and angular measurements. Results The obtained data revealed that the mean values were approximately ranging from 6.7 to 7.2 mm for pedicle height, 4.4 to 4.9 mm for pedicle width, 22.2 to 27.7 mm for pedicle axis length, 42.3° to 51.5° for transverse angle, and 5.2° to 14.1° for sagittal angle. Conclusion Linear measurements of pedicle dimensions and also axial angles from horizontal and vertical planes may provide some anatomic limitations for subaxial cervical transpedicular screw fixation, and also contribute to the safety of the surgical procedure.
What problem does this paper attempt to address?