Distribution of wind load on symmetrical double- tower tall building

沈国辉,孙炳楠,楼文娟,燕辉,顾正维
DOI: https://doi.org/10.3321/j.issn:1000-6869.2003.01.011
2003-01-01
Abstract:In the paper, a wind tunnel test was conducted on a double tower tall building. The resultant wind loads on the sections of one tower are calculated with the data obtained from the test. The global body shape coefficients along the structural axes are then determined by back calculation which can simplify the results of wind tunnel test and be applied directly to the engineering structure design. The characteristics of wind load distribution on double tower tall building are discussed and the global body shape coefficients are proposed under various wind azimuths. The torsional moment due to wind load on the towers of the building should be taken into account through introducing the torsion magnifying coefficients.
What problem does this paper attempt to address?