Abstract:Objective: To evaluate the diagnostic value of MRCP combined with oblique-coronal T2WI scanning in biliary obstructive diseases. Methods: Conventional MRI coronal T2WI, MRCP and oblique-coronal T2WI(taken conventional coronal view as standard tilted toward dorsal 30°) were performed in 80 patients with suspected biliary obstructive diseases. Results: In the same plane, the sensitivity of showing ductus hepaticus and ductus hepaticus communis, ductus choledochus with MR oblique-coronal T2WI was superior to conventional MR coronal T2WI. The accuracy in showing the nature of focus size, border shape of narrowing, length of the narrow segment(1.0cm) and direction of biliary duct modification with MRCP combined with MRI oblique-coronal T2WI were superior to MRCP in conventional MRI coronal T2WI. Conclusion: So MRCP combined with oblique-coronal T2WI, has its advantage, it can determine the nature and location of lesion in biliary obstructive diseases.