Research on coagulation of unwashed shed blood after total knee arthroplasty

关振鹏,吕厚山,魏威,田京,艾京
DOI: https://doi.org/10.3760/j.issn:0253-2352.2003.02.003
2003-01-01
Abstract:Objective To evaluate the quality of unwashed and filtered shed blood and the safety of coagulation while refusing this kind of blood to patients after total knee replacement. Methods From May 2000 to July 2000, 30 patients underwent total knee replacement consecutively. All patients received blood transfusion of unwashed autologous wound drainage blood from the operative knees, and the drainage blood was collected routinely by ConstaVacTM blood conservation system (Stryker Company). Coagulative factors from patients peripheral blood before and after the operation and shed blood were measured, such as fibrinogen, AT-Ⅲ, D-Dimer and plasminogen. PT and APTT were also measured. There were 7 males and 23 females, with the average age of 56.9 years old (29-75 years); 15 patients were diagnosed as osteoarthritis, 15 patients were rheumatoid arthritis. 14 cases underwent unilateral TKR and 16 bilateral TKR. Results 1) The levels of plasminogen, AT-Ⅲ in postoperative peripheral blood (6 hours after surgery) and shed blood (2-6 hours after surgery) were lower than those of preoperative peripheral blood; the levels of plasminogen, AT-Ⅲ in shed blood (2-6 hours after surgery) were also lower than those of postoperative peripheral blood (6 hours after surgery). All of the differences were significant by t-test with the confidence of 99%. 2) There was no fibrinogen in postoperative wound drainage blood, and 6-hour postoperative peripheral blood fibrinogen level was significantly lower than preoperative blood fibrinogen level. 3) All the values above were almost in normal range. No clinical evidence of coagulation and DIC was noted in these patients after transfusion of unwashed autologous wound drainage blood. 4) All the values of D-Dimer in preoperative blood were normal (under 200 ng/ml), but those in postoperative peripheral blood (6 hours after surgery) and shed blood (2-6 hours after surgery) were almost above 2 000 ng/ml. 5) Sex, operation method and diagnosis had no effects on coagulative factors. Conclusion There are significant changes of coagulative factors in unwashed, filtered shed blood after total knee replacement, it may produce a risk of coagulopathy due to refusal of this kind of blood, in fact, autologous wound drainage blood appears to be relatively safe to patients clinically.
What problem does this paper attempt to address?