Abstract:During storage and discharging process of zinc-air battery,electrolyte may penetrate into gas diffusion electrode ceaselessly due to capillary force.Chemical reaction activating area,thereby the discharging performance,is determined by infusion mass and distribution of electrolyte penetrated into gas diffusion electrode.Relationship between the infusion mass and discharging performance in 4days after electrolyte penetration beginning was experimentally studied,and with the support of topology network,the process of electrolyte penetration into porous media was numerically simulated.Results indicate that along with the penetration process,the infusion mass and its distribution keep changing,the discharging performance of gas diffusion electrode can be divided into three stages:when infusion saturation degree reaches 39.4%,electrode presents the best discharging performance;from 2-24hours after electrolyte penetration beginning,penetration develops quickly,when infusion saturation degree reaches 81%,discharging performance declines slightly;after 24hours,penetration growth slow down sharply,and the discharge power dropped significantly with the increase of infusion.