Hydrogen pumping activation and galvanostatic charge measurement for PEMFC

Man-cun SONG,Pu-cheng PEI,Hua-chi XU,Xia ZENG
DOI: https://doi.org/10.3969/j.issn.1002-087X.2015.04.045
2015-01-01
Abstract:The performance of proton exchange membrane fuel cell(PEMFC) wil decline after long period on standby, and the hydrogen pumping is an effective activation. The humidified hydrogen and nitrogen are pumped into PEMFC separately, while external current is introduced to recover proton conductivity of MEA. A galvanostatic charge measurement was investigated in the hydrogen pumping activation process of a decayed one-piece PEMFC after long period on standby. The variation of the electrochemical active surface, hydrogen crossover current, electric double layer capacitance and ohmic resistance was studied. The results show that al of the parameters remain basical y stable after 1 h activation, the open circuit voltage increases by 14%, the maximum power increases by 121.2%, and the ohmic resistance decreases by 6.8%. In the cathode, the electrochemical active surface increases by 42.4%, while the electric double layer capacitance shows little change. The galvanostatic charge measurement can also be applied to multi-parameter measurement of PEMFC stacks.
What problem does this paper attempt to address?